* Copyright (c) 2019 Vestas Wind Systems A/S |
|
* |
|
* Based on clock_control_mcux_sim.c, which is: |
|
* Copyright (c) 2017, NXP |
|
* |
|
* SPDX-License-Identifier: Apache-2.0 |
|
*/ |
|
|
|
#define DT_DRV_COMPAT nxp_kinetis_mcg |
|
|
|
#include <zephyr/drivers/clock_control.h> |
|
#include <zephyr/dt-bindings/clock/kinetis_mcg.h> |
|
#include <soc.h> |
|
#include <fsl_clock.h> |
|
|
|
#define LOG_LEVEL CONFIG_CLOCK_CONTROL_LOG_LEVEL |
|
#include <zephyr/logging/log.h> |
|
LOG_MODULE_REGISTER(clock_control_mcg); |
|
|
|
static int mcux_mcg_on(const struct device *dev, |
|
clock_control_subsys_t sub_system) |
|
{ |
|
return 0; |
|
} |
|
|
|
static int mcux_mcg_off(const struct device *dev, |
|
clock_control_subsys_t sub_system) |
|
{ |
|
return 0; |
|
} |
|
|
|
static int mcux_mcg_get_rate(const struct device *dev, |
|
clock_control_subsys_t sub_system, |
|
uint32_t *rate) |
|
{ |
|
clock_name_t clock_name; |
|
|
|
switch ((uint32_t) sub_system) { |
|
#if defined(FSL_FEATURE_MCG_FFCLK_DIV) && (FSL_FEATURE_MCG_FFCLK_DIV) |
|
case KINETIS_MCG_FIXED_FREQ_CLK: |
|
clock_name = kCLOCK_McgFixedFreqClk; |
|
break; |
|
#endif |
|
case KINETIS_MCG_OUT_CLK: |
|
*rate = CLOCK_GetOutClkFreq(); |
|
return 0; |
|
default: |
|
LOG_ERR("Unsupported clock name"); |
|
return -EINVAL; |
|
break; |
|
} |
|
|
|
*rate = CLOCK_GetFreq(clock_name); |
|
return 0; |
|
} |
|
|
|
static DEVICE_API(clock_control, mcux_mcg_driver_api) = { |
|
.on = mcux_mcg_on, |
|
.off = mcux_mcg_off, |
|
.get_rate = mcux_mcg_get_rate, |
|
}; |
|
|
|
DEVICE_DT_INST_DEFINE(0, NULL, NULL, NULL, NULL, PRE_KERNEL_1, |
|
CONFIG_CLOCK_CONTROL_INIT_PRIORITY, |
|
&mcux_mcg_driver_api);
|
|
|