Primary Git Repository for the Zephyr Project. Zephyr is a new generation, scalable, optimized, secure RTOS for multiple hardware architectures.
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 
Benjamin Cabé ee77704715 samples: sensor: use zephyr:code-sample directive 10 months ago
..
boards boards: silabs: Consistently name dev kits 1 year ago
src
CMakeLists.txt
Kconfig
README.rst samples: sensor: use zephyr:code-sample directive 10 months ago
prj.conf
sample.yaml boards: silabs: Consistently name dev kits 1 year ago

README.rst

.. zephyr:code-sample:: ccs811
:name: CCS811 indoor air quality sensor
:relevant-api: sensor_interface

Get CO2 equivalent and VOC data from a CCS811 sensor.

Overview
********

The CCS811 digital gas sensor detects volatile organic compounds (VOCs)
for indoor air quality measurements. VOCs are often categorized as
pollutants and/or sensory irritants and can come from a variety of
sources such as construction materials (paint and carpet), machines
(copiers and processors), and even people (breathing and smoking). It
estimates carbon dioxide (CO2) levels where the main source of VOCs is
human presence.

Building and Running
********************

Building and Running on thingy52/nrf52832
=========================================

.. zephyr-app-commands::
:zephyr-app: samples/sensor/ccs811
:board: thingy52/nrf52832
:goals: build flash
:compact:


Sample Output
=============

The sample output below is from a `Nordic Thingy:52
<https://www.nordicsemi.com/Software-and-tools/Prototyping-platforms/Nordic-Thingy-52>`_
(thingy52/nrf52832) that includes this sensor (and others).
After a soft reset, there is a 5-second startup period
where readings are unstable, and then we can see steady
reported measurements of about 400 ppm eC02 and 0 ppb eTVOC.

.. code-block::console

*** Booting Zephyr OS build zephyr-v2.1.0-310-g32a3e9907bab ***
device is 0x20001088, name is CCS811
HW 12; FW Boot 1000 App 1100 ; mode 10

[0:00:00.046]: CCS811: 65021 ppm eCO2; 65021 ppb eTVOC
Voltage: 0.000000V; Current: 0.000000A
BASELINE fff4
Timed fetch got 0

[0:00:01.059]: CCS811: 65021 ppm eCO2; 65021 ppb eTVOC
Voltage: 0.000000V; Current: 0.000000A
BASELINE fff4
Timed fetch got 0
Timed fetch got stale data
Timed fetch got stale data
Timed fetch got stale data

[0:00:05.084]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
Voltage: 0.677040V; Current: 0.000014A
BASELINE 8384
Timed fetch got 0

[0:00:06.096]: CCS811: 405 ppm eCO2; 0 ppb eTVOC
Voltage: 0.675428V; Current: 0.000014A
BASELINE 8384
Timed fetch got 0

[0:00:07.108]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
Voltage: 0.677040V; Current: 0.000014A
BASELINE 8384
Timed fetch got 0

[0:00:08.121]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
Voltage: 0.677040V; Current: 0.000014A
BASELINE 8384
Timed fetch got 0

[0:00:09.133]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
Voltage: 0.677040V; Current: 0.000014A
BASELINE 8384
Timed fetch got 0

[0:00:10.145]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
Voltage: 0.677040V; Current: 0.000014A
BASELINE 8384
Timed fetch got 0