Enable the RTC-domain and main digital regulators early in clock init, then load and program the factory/runtime calibrated bias values for high-power and low-power regulators into the PMU. This ensures the correct voltage/current settings for stable, low-noise clock operation in active, modem and sleep modes. Signed-off-by: Sylvio Alves <sylvio.alves@espressif.com>pull/90162/merge